3. Appendix: Service Call Conditions
997
C
3
998
B
48
Application function selection error
The application selected by a key press
on the operation panel does not start or
ends abnormally.
Application start error
After switching the machine on, the
application does not start within 60 s.
(No applications start or end normally.)
• Software for that application is
defective
• An option required by the application
(RAM, DIMM, board) is not installed.
• Too complicated nest of the fax group
address
1. As for the fax operation problem,
simplify the nest of the fax group
address.
• Software for that application is
defective
• An option required by the application
(RAM, DIMM, board) is not installed.
1. Check the setting of SP5875-001. If
the setting is set to "1 (OFF)", change
it to "0 (OFF)".