2929 1 Upper
2929 2 Lower
2994*
ID Detect Temp
Adjusts the temperature threshold. The ID sensor signal is not referenced when the fusing
2994 1
temperature is at the specified level or higher while the copier is recovering or starting up.
2996*
T Roller Cleaning
Cleans or does not clean the transfer roller before each job. Select "1" if the backside of
2996 1
the paper becomes unclean when output. Note that the copier takes a longer time to output
the first copy when you select "1". If you select "0", the transfer roller is never cleaned.
2998*
Main Mag- print
Adjusts the magnification (
2998 1
and Adjustment"). The specification is 100 ± 1.0%.
SP4-XXX (Scanner)
4008*
Sub-Scan Magnification (Scanner)
Adjusts the sub-scan magnification (
4008 1
"Replacement and Adjustment").
4009*
Main Scan Magnification (Scanner)
Adjusts the main-scan magnification (
4009 1
"Replacement and Adjustment").
4010*
Leading Edge Scan Registration
Adjusts the leading edge registration (
4010 1
"Replacement and Adjustment").
4011*
Side-to-side Scan Regist
System Service Mode (Basic: D067/D072)
[0.50 to 3.50 / 3.20 / 0.01V/step] DFU
[0.50 to 3.50 / 0.70 / 0.01V/step] DFU
[30 to 90 / 30 / 1 °C/step]
[0 = No / 1 = Yes]
[–0.5 to +0.5 / 0.0 / 0.1%/step]
"Adjusting Copy Image Area" in the section "Replacement
[-0.9 to +0.9 / 0.0 / 0.1%/step]
"Adjusting Copy Image Area" in the section
[–0.9 to +0.9 / 0.0 / 0.1%/step]
"Adjusting Copy Image Area" in the section
[–5.0 to +5.0 / 0.0 / 0.1 mm/step]
"Adjusting Copy Image Area" in the section
[–2.0 to +2.0 / 0.0 / 0.1 mm/step]