Figure 27: Rmon Alarm Configuration - LevelOne GEL-2670 User Manual

24 ge + 2 ge sfp l2 managed switch
Table of Contents

Advertisement

| Configuring the Switch
C
4
HAPTER
Configuring Security
W
I
EB
NTERFACE
To configure an RMON alarm:
Click Advanced Configuration, Security, Switch, RMON, Alarm.
1.
Click Add New Entry.
2.
Enter an index number, the polling interval, the MIB object to be polled
3.
(etherStatsEntry.n.n), the sample type, the alarm startup type, the
thresholds, and the event to trigger.
Click Save.
4.

Figure 27: RMON Alarm Configuration

C
RMON E
ONFIGURING
Use the RMON Event Configuration page to set the action to take when an
alarm is triggered. The response can include logging the alarm or sending a
message to a trap manager. Alarms and corresponding events provide a
way of immediately responding to critical network problems.
P
ATH
Advanced Configuration, Security, RMON, Event
P
ARAMETERS
The following parameters are displayed:
ID – Index to this entry. (Range: 1-65535)
Desc – A comment that describes this event. (Range: 0-127
characters)
Type – Specifies the type of event to initiate:
none – No event is generated.
log – Generates an RMON log entry when the event is triggered.
Log messages are processed based on the current configuration
settings for event logging (see
on page
56).
snmptrap – Sends a trap message to all configured trap managers
(see
"Configuring SNMP System and Trap Settings" on page
logandtrap – Logs the event and sends a trap message.
– 86 –
VENTS
"Configuring Remote Log Messages"
72).