Data Source – Port identifier.
◆
W
I
EB
NTERFACE
To enable regular sampling of statistics on a port:
Click Advanced Configuration, Security, Switch, RMON, Statistics.
1.
Click Add New Entry.
2.
Enter the index identifier and port number.
3.
Click Save.
4.
Figure 25: RMON Statistics Configuration
C
RMON H
ONFIGURING
Use the RMON History Configuration page to collect statistics on a physical
interface to monitor network utilization, packet types, and errors. A
historical record of activity can be used to track down intermittent
problems. The record can be used to establish normal baseline activity,
which may reveal problems associated with high traffic levels, broadcast
storms, or other unusual events. It can also be used to predict network
growth and plan for expansion before your network becomes too
overloaded.
P
ATH
Advanced Configuration, Security, RMON, History
C
U
OMMAND
SAGE
The information collected for each sample includes: drop events, input
octets, packets, broadcast packets, multicast packets, CRC alignment
errors, undersize packets, oversize packets, fragments, jabbers, collisions,
and network utilization.
P
ARAMETERS
The following parameters are displayed:
ID - Index to this entry. (Range: 1-65535)
◆
Data Source – Port identifier.
◆
Interval - The polling interval. (Range: 1-3600 seconds; Default: 1800
◆
seconds)
– 83 –
C
HAPTER
S
ISTORY
AMPLES
| Configuring the Switch
4
Configuring Security