Module Rear
Ports
Description
ANALOG
RJ45 socket. Used for connection to analog trunks. Ports can be configured as either loop-start or
390
ground-start trunks through the IP Office configuration.
In the event of power failure, Analog ports 1 and 2 are directly connected to analog extension ports PF1
and PF2 respectively. If used the connected phones must be clearly labeled as power failure devices. This
is only supported for loop-start analog trunks.
DC I/P
DC power input port. Used for connection of the power lead from an Avaya 40W external power supply
393
unit supplied with the expansion module. A locale specific
PSU is required but is not supplied with the module.
DTE
25-Way D-Type socket. For Avaya use only.
EXPANSION
RJ45 Socket. Used for direct connection to an Expansion port on an IP Office control unit using the
395
Expansion Interconnect cable supplied with the module.
PF
RJ45 socket. Power failure analog extension ports. See Analog section above.
397
Ground point. Used for connection of a
screw is not present, the top-center cover screw should be used instead.
· IMPORTANT
In all IP Office installations, any module being used for analog trunk connections must be connected to
a
functional earth
WARNING
·
Within areas of high lightning risk, any module using analog trunk connections must be connected to
a
protective ground
Part Codes and Related Equipment
All expansion modules are supplied with a base software level and should be upgraded to match the core software of the
control unit in the IP Office system. Expansion modules include an external power supply unit (PSU) and an appropriate
interconnect cable. They do not include a locale specific power cord for the external PSU or any phone extension cables.
Item
IPO IP500 EXP MOD ANLG TRNK 16
IPO IP500 EXP MOD ANLG TRNK 16 TAA
IEC60320 C7 Power Cord
Mounting Kit
205
Installing IP500/IP500 V2
IP Office 9.0
functional earth
.
44
and to
surge protection equipment
44
Variant
America
"
Trade Agreements Act
compliant variant.
NEMA1-15
IPO IP500 RACK MNTG
KIT V3
IEC60320 C7 power cord
if required. On older modules where this
44
.
45
Country
America
America
421
America
All
15-601042 Issue 28c (19 August 2013)
for the external
39
SAP Code
700449473
700501511
700213390
700503160
Page 242