Control Unit Cards; Ip500 Base Cards - Avaya IP500 V2 Installation Manual

Hide thumbs Also See for IP500 V2:
Table of Contents

Advertisement

1.8 Control Unit Cards

1.8.1 IP500 Base Cards

IP500 Digital Station Base Card
IP500 Analog Phone Base Card
IP500 TCM8 Digital Station Card
IP500 VCM Base Card
Installing IP500/IP500 V2
IP Office 9.0
The IP500 and IP500 V2 control units have 4 slots for the insertion of
IP500 base cards. The slots are numbered 1 to 4 from left to right.
Normally they can be used in any order, however if the capacity for a
particular type of card is exceeded, the card in the rightmost slot will be
disabled.
Each base card includes an integral front panel with ports for cable
connections. Typically the first 8 ports on the left are for connection of
extension devices. The 4 ports on the left are used for connection of trunks
if a
trunk daughter card
227
This card provides 8 DS (digital station) ports for the connection of
Avaya digital phones.
· The card can be fitted with an
uses the base card ports for trunk connection.
· Maximum: 3 per control unit.
· 4400 Series phones (4406D, 4412D and 4424D) are not
· Connections for 4100, 7400, M-Series and T-Series phones use
221
The card is available in two variants, supporting either 2 or 8 analog
phone ports.
· The card can be fitted with an
uses the base card ports for trunk connection.
· Maximum: 4 per control unit.
· The analog phone ports do not include a ringing capacitor. Where
· If fitted with an IP500 Analog Trunk daughter card, during power
231
This card provides 8 TCM (digital station) ports for the connection of
Avaya 4100, 7400, M-Series and T-Series phones.
· The card can be fitted with an
uses the base card ports for trunk connection.
· Maximum: 4 per control unit per IP500 V2 control unit. Not
supported by IP500 control units.
232
This card is available in variants supporting either 32 or 64 voice
compression channels for use with VoIP calls.
· The card can be fitted with an
uses the base card ports for trunk connection.
· Maximum: 2 per control unit.
is added to the base card.
29
supported on this card. They are supported on external
expansion module DS ports.
the IP500 TCM8 Digital Station card.
this is a requirement, connection should be via a Master socket
containing ringing capacitors.
failure phone port 8 is connected to analog trunk port 12.
IP500 trunk daughter card
IP500 trunk daughter card
IP500 trunk daughter card
IP500 trunk daughter card
15-601042 Issue 28c (19 August 2013)
which
29
which
29
which
29
which
29
Page 26

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ip500

Table of Contents