8.1.2 Shutdown a System Using System Status Application

To shutdown a system using System Status Application
1. Start
System Status
2. In the navigation panel select System.
3. At the bottom of the screen select Shutdown System.
4. Select the time duration for the shutdown or indefinite.
5. Click OK.
6. Wait until the LEDs on the front of the system are all fast flashing red before performing any other actions.

8.1.3 Shutdown a System Using a System Phone

This process can be used by a user configured as a System Phone user and using a 1400, 1600, 9500 or 9600 Series
phone (excluding XX01, XX02 and XX03 models). The user's Login Code is used to restrict access to the system
administration functions on the phone.
Unlike IP Office Manager, a system phone user cannot select an indefinite shutdown. They can set a timed shut down of
between 5 minutes and 24 hours.
To shutdown a system using a system phone
1. Select Features | Phone User | System Admin.
2. Enter your IP Office user login code.
3. From the menu select System Shutdown.
4. Select a time period for the shutdown. It must be in between 5 minutes and 24 hours.
5. Press Done and then Confirm to begin the shutdown.
6. Wait until the LEDs on the front of the system are all fast flashing red before performing any other actions.

8.1.4 Shutdown a System Using the AUX Button

This method is supported by IP500 V2 control units.
To shutdown a system using the IP500 V2 AUX Button
1. On the rear of the control unit, press and hold the AUX button for more than 5 seconds.
2. The control unit will shutdown with the restart timer set to 10 minutes.
3. Wait until the LEDs on the front of the system are all fast flashing red before performing any other actions.

8.1.5 Shutdown a System Using IP Office Web Manager

To shutdown a system using IP Office Web Manager
1. Login to IP Office Web Manager.
a. Enter the systems IP address in the browser. Select IP Office Web Manager. Alternatively, enter https://
<IP_Address>:8443/WebMgmtEE/WebManagement.html.
b. Enter an administrator user name and password and click Login.
2. Click Advanced and select System Shutdown.
3. Click OK.
4. Wait until the LEDs on the front of the system are all fast flashing red before performing any other actions.
Installing IP500/IP500 V2
IP Office 9.0
and access the IP Office's status output.
71
15-601042 Issue 28c (19 August 2013)
Page 146

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ip500

Table of Contents