Subnet Based Vlans - ZyXEL Communications GS2200-24 User Manual

Intelligent layer 2gbe switch
Hide thumbs Also See for GS2200-24:
Table of Contents

Advertisement

Chapter 9 VLAN
Table 17 Advanced Application > VLAN > VLAN Port Setting (continued)
LABEL
*
PVID
GVRP
Acceptable
Frame Type
VLAN Trunking
Isolation
Apply
Cancel

9.7 Subnet Based VLANs

Subnet based VLANs allow you to group traffic into logical VLANs based on the
source IP subnet you specify. When a frame is received on a port, the Switch
checks if a tag is added already and the IP subnet it came from. The untagged
packets from the same IP subnet are then placed in the same subnet based VLAN.
One advantage of using subnet based VLANs is that priority can be assigned to
traffic from the same IP subnet.
96
DESCRIPTION
Settings in this row apply to all ports.
Use this row only if you want to make some settings the same for all
ports. Use this row first to set the common settings and then make
adjustments on a port-by-port basis.
Note: Changes in this row are copied to all the ports as soon as you
make them.
A PVID (Port VLAN ID) is a tag that adds to incoming untagged frames
received on a port so that the frames are forwarded to the VLAN group
that the tag defines.
Enter a number between 1and 4094 as the port VLAN ID.
Select this check box to allow GVRP on this port.
Specify the type of frames allowed on a port. Choices are All, Tag Only
and Untag Only.
Select All from the drop-down list box to accept all untagged or tagged
frames on this port. This is the default setting.
Select Tag Only to accept only tagged frames on this port. All untagged
frames will be dropped.
Select Untag Only to accept only untagged frames on this port. All
tagged frames will be dropped.
Enable VLAN Trunking on ports connected to other switches or routers
(but not ports directly connected to end users) to allow frames
belonging to unknown VLAN groups to pass through the Switch.
Select this to allows this port to communicate only with the CPU
management port and the ports on which the isolation feature is not
enabled.
Click Apply to save your changes to the Switch's run-time memory. The
Switch loses these changes if it is turned off or loses power, so use the
Save link on the top navigation panel to save your changes to the non-
volatile memory when you are done configuring.
Click Cancel to begin configuring this screen afresh.
GS2200-24 User's Guide