Ink discharge way cleaning [Disway WASH]
The ink discharge way may become clogged by coagulated ink. It must be cleaned at
regular intervals to avoid clogging.
Ink discharge way: Tubing between the cap and the waste ink tank
• When cleaning the ink station and head, be sure to wear the supplied
goggle and gloves since you may get ink in your eyes.
• Do not move the carriage out of the capping station by hand. Use the appro-
priate operation key to move the carriage.
Cleaning tools
•
Cleaning fluid RS for maintenance (SPC-0336)
•
Pipette
•
Glove
STEP
1. Press the [FUNCTION] key.
2. Press the [ ] and [ ] key until the display
gives the indication [MAINTENANCE].
3. Press the [ENTER] key.
[STATION] is displayed.
4. Press the [ENTER] key.
[CARRIAGE out] is displayed.
5. Press the [ ] and [ ] key until the display
gives the indication [Disway WASH].
6. Press the [ENTER] key.
The carriage moves to the platen.
Dry suction starts in cycles consisting of 5 seconds of suction
followed by 10 seconds of pause.
- 5.13 -
FUNCTION
SET UP
< ENT >
FUNCTION
MAINTENANCE
< ENT >
MAINTENANCE
STATION
STATION
MENT : CARRIAGEout
STATION
MENT : Disway WASH
STATION
COMPLETED
< ent >
: ent