Setting Exhaust Fan And Drier Fan - MIMAKI JV3-75 SP II Operation Manual

Table of Contents

Advertisement

Setting exhaust fan and drier fan

The following sets up the rotational operation of the exhaust fan which lets out the order of ink and
the drier fan which used to provide cool air for drying the media after plotting.
STOP TIME
Stops rotation of the exhaust fan and the drier fan at the specified period of time interval after
plotting.
CONT. :
0- 240 min :
RENEW
Selects the current status of the exhaust fan and the drier fan.
(HIGH, LOW, OFF)
STEP
1. Make sure that the mode is LOCAL mode.
2. Press the [FUNCTION] key.
3. Select the [DRYING FAN] by pressing the JOG
keys [ ] and [ ].
4. Press the [ENTER] key.
5. Select the [STOP TIME] or [RENEW] by press-
ing the JOG keys [ ] and [ ], and then set the
value.
Rotates the fan at a HIGH speed.
Set up the period of time after plotting when the fan is to be sopped. When the plotter
starts operation, the fan starts rotation accordingly. (During plotting, the fan is rotating
at a high speed.)
- 4.12 -
< LOCAL >
width : 1272 mm
FUNCTION
SET UP
< ENT >
FUNCTION
DRYING FAN
< ENT >
DRYING FAN
STOP TIME
< ent >
DRYING FAN
STOP TIME
< ent >
DRYING FAN
RENEW
< ent >