Ink discharge way cleaning [STATION]-[Disway WASH]
The ink discharge way may become clogged by coagulated ink. It must be cleaned at
regular intervals to avoid clogging.
Ink discharge way: Tubing between the cap and the waste ink tank
• When cleaning the ink station and head, be sure to wear the supplied
goggle and gloves since you may get ink in your eyes.
• Do not move the carriage out of the capping station by hand. Use the appro-
priate operation key to move the carriage.
Cleaning tools
•
Cleaning fluid RS for maintenance (SPC-0336)
•
Pipette
•
Glove
STEPS:
1. Select the [STATION].
page 5.2.
2. Press the [ENTER] key.
3. Select the [Disway WASH].
4. Press the [ENTER] key.
The carriage moves to the platen.
Dry suction starts in cycles consisting of 5 seconds of suction
followed by 10 seconds of pause.
- 5.7 -
MAINTENANCE
STATION
< ent >
STATION
MENT : CARRIAGEout
STATION
MENT : Disway WASH
STATION
COMPLETED
: ent