Sleep cleaning [SLEEP clean]
To prevent clogging while the power switch has been turned off, ink is ejected from the
head at regular intervals.
The head itself must be cleaned also at regular intervals which are set as shown below.
STEP
1. Press the [FUNCTION] key.
2. Press the [ ] key until the display gives the
indication [MAINTENANCE].
3. Press the [ENTER] key.
[STATION] is displayed.
4. Press the [ ] key until the display gives the
indication [SLEEPclean].
3. Press the [ENTER] key.
5. Press the JOG-key [ ] or [ ] as needed to
select the interval.
4h, 8h, 12h, 24h, OFF
6. Press the [ENTER] key.
[SLEEPclean] is displayed.
7. Press the [END] key twice.
This returns the device to LOCAL mode.
TWICE
- 5.15 -
FUNCTION
SET UP
< ENT >
FUNCTION
MAINTENANCE
< ENT >
MAINTENANCE
STATION
MAINTENANCE
SLEEPclean
SLEEPclean
INTERVAL
= 8h
SLEEPclean
INTERVAL
= 12h
MAINTENANCE
SLEEPclean
< LOCAL >
< ent >
< ent >
< ent >