Use the cleaning kit

In case the internal section is dirty or if nozzle missing cannot be resolved even after cleaning (
page 2.21, 4.10), use the cleaning kit.
The cleaning kit contains the following items. Do not use alcohol or water.
When using the supplied maintenance cleaning fluid, be sure to wear the supplied protective glasses.
Cleaning fluid RS for maintenance (SPC-0336)
Dropper
Cotton bud
Glove

Cleaning the station interior

STEP
1. Press the [FUNCTION] key.
2. Press the [ ] and [ ] key until the display
gives the indication [MAINTENANCE].
3. Press the [ENTER] key.
[STATION] is displayed.
4. Press the [ENTER] key.
[CARRIAGE out] is displayed.
5. Press the [ENTER] key.
Move the carriage on the platen.
6. Open the front cover.
7. Dampen a cotton bud with cleaning fluid.
8. Using the cotton bud dampened with cleaning
fluid, wipe out dirt on the wiper and around the
cap.
Be careful not to leave lint of the cotton bud. Lint
may cause plotting failure.
9. Close the front cover.
10. Press the [ENTER] key.
The carriage return to the capping station, and the initial
operation is performed.