Off Reduction — The channel attenuation when a mic channel gates off.
Range is 0.0 dB to 100.0 dB attenuation (0 to – 100 dB).
Default: 60.0 dB.
Attack Time — Sets the time at which gain is applied after a channel gates on.
Range is 0.0 msec to 3000.0 msec in 0.1 msec increments.
Default: 10.0 msec.
Hold Time — The time that a mic remains active after the signal drops below a
user-defined threshold.
Range is 0.0 msec to 10000.0 msec in 0.1 msec increments.
Default: 400.0 msec.
Release Time — The time it takes to ramp the signal level to the Off Reduction value
when the mic channel gates off.
Range is 10.0 msec to 10000.0 msec in 0.1 msec increments.
Default is 100.0 msec.
Gate Status Indicator and meter — The meter provides real-time sampling of the
selected AM channel with a digital readout of the current level the meter. The indicator
lights when the channel is shut off.
To insert an automix block into a channel:
1.
Insert an AM processing block in the desired channel.
Either:
Right-click the AM block and select Insert
Automixer, or
Double-click the AM block and select Automixer.
2.
Double-click the inserted AM block to open it (see
page 55).
The AM block defaults to Bypass (bypass button red). Click Bypass to toggle the AM
block to active (bypass button gray).
Automix parameters:
on
DMP 128 • Software Control