Noise Gate - Extron electronics DMP 128 User Manual

Digital matrix processor
Hide thumbs Also See for DMP 128:
Table of Contents

Advertisement

Noise Gate

The noise gate allows an input signal to pass only when it exceeds a specified threshold
level. Above the threshold level, the signal passes unprocessed; below the threshold the
signal is attenuated at the rate set by the ratio adjustment. The typical setting of the noise
gate threshold is just above the noise level of the environment or source equipment. That
allows signals that are above the noise to pass, and attenuates the noise when there is no
signal to eliminate background noise. Click in each field or use the sliders to change the
values.
Threshold — is the input signal level below
which attenuation (gating) begins (subject to
attack time) and above which gating stops
(subject to hold and release time).
The threshold level can be adjusted from -80.0
to 0.0 dB in 0.1 dB increments.
Default is -65.0 dB.
Max Attenuation — is the maximum
attenuation of the signal when it drops below
the threshold.
Maximum attenuation can be adjusted from
0.0 to 80.0 dB in 0.1 dB increments.
Default is 25.0 dB.
Ratio — is the input signal level reduction
when gating is engaged.
The ratio can be adjusted from 1.0 to 100.0 in
0.1 increments.
Default is 20.0:1.
Attack Time — adjusts the time delay for
gating to engage after the input signal level
drops below the threshold level.
Attack time can be adjusted from 0.0 to 200.0
ms in 0.1 ms increments.
Default is 1.0 ms.
Hold Time — adjusts how long gating continues after the input signal drops below the
threshold. If the signal is still below the threshold when hold time ends, release time begins.
Hold time can be adjusted from 0.0 to 500.0 ms in 0.1 ms increments.
Default is 300.0 ms.
Release Time — adjusts the time it takes to return the signal to normal (unprocessed)
levels after the signal is no longer below the threshold level setting. Release time begins only
after hold time is reached.
Release time can be adjusted from 10 to 1000.0 ms in 0.1 ms increments.
Default is 1000.0 ms.