Command and Response Table for Basic SIS Commands (continued)
Command
ASCII command
(host to device)
Serial Port
E
Send data string
E
Configure
parameters
E
View serial port
parameters
E
Configure receive
timeout
E
View receive
timeout
Digital I/O Port
X!
View I/O mode
X!
View I/O state
X!
NOTES:
= Port number
X1&
= Command string wait time
X2)
= Character wait time
X2!
= Length of stream or delimiter
X2#
= Priority status for receiving
timeouts (default: 0)
X2%
= Baud rate (default: 9600)
X2^
= Parity (default: N)
X2&
= Data bits
X2*
= Stop bits
X2(
= Command data section
X4)
= I/O mode
X4#
= I/O state
* X1& * X2) * X2!
} X@
1
RS
* X2% , X2^ , X2& , X2*
}
1
CP
}
1CP
* X1& * X2) * X2# * X2!
}
1
CE
}
1CE
[
]
01 to 99
0-32767 in tens of milliseconds
0-32767 in tens of milliseconds
L=Byte count (00 – 32767), D=decimal value for ASCII character
(0-00255)
0=Send data string command parameters if they exist
1=Configure receive timeout command parameters.
300,600,1200,1800,2400,3600,4800,7200,9600,14400,19200
38400,57600,115200
O=odd
E=even
N=none
M=mark
S=space
7, 8 (default=8)
1, 2 (default=1)
For Web encoding only: Data will be directed to specified port and
encoded if non-alphanumeric. Since data can include either command
terminator, they must be encoded as follows when used within the data section:
20
Space (Hex:
) is encoded as
0=input
1=output
0=off
1=on
Response
(device to host)
]
response
X2% , X2^ , X2& , X2*]
Cpn1
Ccp
X2% , X2^ , X2& , X2* ]
X1& , X2) , X2# , X2! ]
Cpn1
Cce
X1& , X2) , X2# , X2! ]
X4) ]
X4# ]
%20
and Plus sign (Hex:
DMP 128 • SIS Programming and Control
Additional description
must
be
2B
%2B.
) is encoded as
138