Setting Audio Levels - Extron electronics DMP 128 User Manual

Digital matrix processor
Hide thumbs Also See for DMP 128:
Table of Contents

Advertisement

Setting Audio Levels

The mix-point level is controlled using SIS commands. The commands template follows a
similar structure as mute and unmute commands.
The audio conversion tables are the same for all mix-points (see
Although a greater range is shown in the table, the minimum and maximum levels are the
same for all mix-points (-35.0 to +25.0 dB).
To select the mix-point, use
In the following example, the audio level of mix-point input 1 to output 1 is set to -10 dB.
The audio level control and mix-point selection formula is:
E
X6)
G
*
X6)
where
according to table 3, is 20000 and the SIS conversion for -10 dB from table 2, is 1948
creating a SIS command
output 1 to -10 dB.
To return the signal level back to default, use the same formula:
E
G20000*2048AU sets the level back to 0 dB.
In this manner, any mix-point can be selected and the signal level between its input and
output changed within the range of -35 to +25 dB.
table 3
beginning on page 176 to find the specific mix-point.
X6!
}
AU
is the mix-point location and
E
G20000*1948AU. This sets the mix-point level at input 1 to
table 2
X6!
is the signal level. The mix-point location
DMP 128 • Reference Information
on page 150).