Advanced Graphic Data Manager
"Application"
menu items
Save cycle
Alarm cycle
Grid division
Min. decade
Only if the grid division is
"Logarithmic"
Max. decade
Only if the grid division is
"Logarithmic"
Display blue
Display
Display black
Display
Display red
Display
Configurable parameters
(factory settings are highlighted in bold)
Specify the save cycle for saving this group during normal operation (see
also limit value / save cycle).
Note: the save cycle is independent of the measured value display.
Note: The recording length available changes depending on the save
cycle set. Tables on the typical recording length are provided in the
technical data.
Picklist: off, 100ms, 1s, to 1min to 1h
Specify the save cycle for saving this group during an alarm condition
(e.g. in the event of limit value violation).
Picklist: off, 100ms, 1s, to 1h
Indicates the number of lines ("amplitude grid") that should be displayed
on the screen in the display mode "Curve". Example: display of 0 to
100%: select 10 divisions, display 0 to 14 pH: select 14 divisions. Picklist:
logarithmic, 1, 2, to 10 to 20
Set the decade as of which the display should be split.
Picklist: 1, 10, 100 to 10000000
Set the decade up to which the display should be split.
Picklist: 1, 10, 100, 10000 to 10000000
Color for displaying the assigned input.
Note: Only the channels that were assigned to a group are saved.
Channels can be assigned to several groups. However, these groups then
have to have the same save cycle (except when the save and alarm cycle
are set to "off").
Picklist: switched off, analog x, digital x, maths x
Please select what data from the selected channel should be displayed.
Picklist: instantaneous value/state,... (depending on the channel
settings)
Color for displaying the assigned input.
Note: Only the channels that were assigned to a group are saved.
Channels can be assigned to several groups. However, these groups then
have to have the same save cycle (except when the save and alarm cycle
are set to "off").
Picklist: switched off, analog x, digital x, maths x
Please select what data from the selected channel should be displayed.
Picklist: instantaneous value/state,... (depending on the channel
settings)
Color for displaying the assigned input.
Note: Only the channels that were assigned to a group are saved.
Channels can be assigned to several groups. However, these groups then
have to have the same save cycle (except when the save and alarm cycle
are set to "off").
Picklist: switched off, analog x, digital x, maths x
Please select what data from the selected channel should be displayed.
Picklist: instantaneous value/state,... (depending on the channel
settings)
Commissioning and use during operation
38105/000 to
38105/009
38110/000 to
38110/009
38115/000 to
38115/009
38120/000 to
38120/009
38125/000 to
38125/009
38130/000 to
38130/009
38135/000 to
38135/009
38140/000 to
38140/009
38145/000 to
38145/009
38150/000 to
38150/009
38155/000 to
38155/009
Direct
access
code
77

Advertisement

Table of Contents
loading

Table of Contents