Advanced Graphic Data Manager
"Inputs" menu
items
Submenu: Fault mode
Only in the Expert setup
Copy settings
Configurable parameters
(factory settings are highlighted in bold)
Totalization
Using the totalization function, the volume (in m) can be calculated from
an analog signal (e.g. flow in m/h). Picklist: no, yes
Totalization base
Select the corresponding time base. Example: ml/s –> time base seconds
(s); m/h –> time base hours (h).
Picklist: second (s), minutes (min), hour (h), day (d)
Total. eng. unit
Here, enter the unit for the volume determined by totalization (e.g. "m").
Low flow cut off
Specify how the device should execute low flow cut off.
Picklist: area around zero point, absolute value
Low flow cut off
Analog values that are lower than the set threshold value (absolute value)
are not integrated ("low flow cut off") User input: 6-digit; factory setting: 0
Calc. factor
Factor for converting the integrated value (e.g. the transmitter returns l/s
–> integration base = second –> desired unit is m –> enter 0.001 as the
factor).
Totalizer: Initial setting for the totalizer. Useful when continuing
measurements recorded to date with an (electro)-mechanical counter.
Factory setting: 0
Settings that specify how this channel behaves in the event of a fault (e.g.
if an input channel has a cable open circuit or the system tries to divide by
0).
In the event of an error
Specify the value/status the unit continues to work with if the result of the
calculation is invalid.
Picklist: last valid value, range start, meas. range end, zero, LOW, HIGH,
free configuration, value is invalid
Note: The picklist entries depend on the "The result is" option.
Error value
(Only if "In event of an error - free configuration" is selected.)
The unit continues calculating with this value if a fault occurs. See table
 Page 58
Fault switches
Switches the selected relay under fault conditions. The terminal numbers
are shown in brackets.
Picklist: not used, relay x (xx-xx)
Note: If there are several reasons for triggering a relay (e.g. 2 different limit
values), this must be set to "Collective relay" under "Setup -> Outputs ->
Relay -> Relay x".
Copies settings from actual channel to selected channel.
Commissioning and use during operation
30100/000 to
Direct
access
code
34000/000 to
34000/007
34005/000 to
34005/007
34010/000 to
34010/007
34015/000 to
34015/007
34020/000 to
34020/007
34025/000 to
34025/007
34035/000 to
34035/039
35000/000 to
35000/007
35005/000 to
35005/007
35010/000 to
35010/007
30100/007
67