Commissioning and use during operation
"Inputs" menu
items
Decimal point
Only for "The result is –
"Instantaneous value" or
"Counter"
Zoom start
Only for "The result is" –
"Instantaneous value"
Zoom end
Only for "The result is" –
"Instantaneous value"
Description ´H´
Only for "The result is – state"
Description ´L´
Only for "The result is – state"
Event message
Only for "The result is – state"
Save event
Only for "The result is – state"
Event text L->H
Can only be saved for "Event
message – acknowledge" or
"Save event – yes"
Event text H->L
Can only be saved for "Event
message – acknowledge" or
"Save event – yes"
Switches relay
Only for "The result is – state"
Totalizer
Only for "The result is - Counter"
or "Operating time"
Submenu: Totalization
Only for "The result is –
instantaneous value"
66
Configurable parameters
(factory settings are highlighted in bold)
Number of places after decimal point for the display. Picklist: 0 to 5 number
of places after the decimal point. This information is only used to better
display the measured value. Factory setting: one (X,Y)
e.g. measured value: 20.12348 l/s
The display shows:
None: 20 l/s
One: 20.1 l/s
Two: 20.12 l/s
Three: 20.123 l/s
Four: 20.1235 l/s
Five: 20.12348 l/s
Note: The value is rounded off where necessary.
If the total value range is not being used then the lower value of the
required range can be entered here. The zoom has no influence on the
storage.
As in "Zoom start". Enter the upper value of the required range here.
Description of the status if the result is "HIGH". This text is both shown in
the display and saved to memory.
Factory setting: on
Description of the status if the result is "LOW". This text is both shown in
the display and saved to memory.
Factory setting: off
"Do not acknowledge": no message is output if the status of the
mathematics channel changes. "Acknowledge": an event message is
displayed and has to be confirmed by pressing a button.
Determines whether the condition change from low to high or high to low
is stored in the event log.
Note: increased memory capacity needed. Picklist: yes, no
Description of condition change from low to high. Event text is stored (e.g.
start filling). 22-character entry.
Description of condition change from high to low. Event text is stored (e.g.
stop filling). 22-character entry.
Outputs the status of the mathematics channel on the selected relay.
Picklist: not used, relay x (xx-xx)
Note: If there are several reasons for triggering a relay (e.g. 2 different limit
values), this must be set to "Collective relay" under "Setup -> Outputs ->
Relay -> Relay x".
Initial setting for the totalizer. Useful when continuing measurements
recorded to date with an (electro)-mechanical counter.
Factory setting: 0
Settings only required if the calculated value is to be integrated for
calculating the volume for example. For analysis periods, see "Signal
analysis".
Advanced Graphic Data Manager
Direct
access
code
30050/000 to
30050/007
30055/000 to
30055/007
30060/000 to
30060/007
30065/000 to
30065/007
30070/000 to
30070/007
30075/000 to
30075/007
30080/000 to
30080/007
30085/000 to
30085/007
30090/000 to
30090/007
30095/000 to
30095/007
30115/000 to
30115/007