Kyocera Mita KM-2530 Service Manual page 96

Hide thumbs Also See for KM-2530:
Table of Contents

Advertisement

2DF
Maintenance
item No.
U020
Initializing all data
Description
Initializes all the backup RAM on the main PCB to return to the original settings.
Purpose
Used when replacing the backup RAM on the main PCB.
Method
1. Press the start key. The screen for executing is displayed.
2. Press EXECUTE on the touch panel. It is displayed in reverse.
3. Press the start key. All data in the backup RAM is initialized, and the original settings for Japan
specifications are set.
When initialization is complete, the machine automatically returns to the same status as when the main
switch is turned on and the display language to the initial setting of English.
Completion
To exit this maintenance item without executing initialization, press the stop/clear key. The screen for selecting
a maintenance item No. is displayed.
U021
Initializing counters and mode settings
Description
Initializes the setting data other than that for adjustments due to variations between respective machines, i.e.,
settings for counters, service call history and mode settings. As a result, initializes the backup RAM according
to the specifications depending on the destination selected in U252.
Purpose
Used to return the machine settings to the factory settings.
Method
1. Press the start key. The screen for executing is displayed.
2. Press EXECUTE on the touch panel. It is displayed in reverse.
3. Press the start key. All data other than that for adjustments due to variations between machines is
initialized based on the destination setting.
Completion
Press the stop/clear key. The screen for selecting a maintenance item No. is displayed.
U022
Initializing data for optical system
Description
Initializes only the data set for the optical section.
Purpose
To be executed after replacing the scanner unit.
Method
1. Press the start key. The screen for executing is displayed.
2. Press SCANNER on the touch panel.
3. Press EXECUTE on the touch panel. It is displayed in reverse.
4. Press the start key. The data for the optical section (U060 to 067, U088 to 099, U403, U990 and U991) is
initialized.
Completion
Press the stop/clear key. The screen for selecting a maintenance item No. is displayed.
1-4-8