Kyocera Mita KM-2530 Service Manual page 654

Hide thumbs Also See for KM-2530:
Table of Contents

Advertisement

Error code
U03500
In confidential polling reception, the specified confidential box No. was not registered in the
destination. Or, in interoffice F-code based bulletin board reception, the specified F-code
confidential box number was not registered in the destination unit. Or, the destination was being
accessed.
U03600
Confidential polling reception was interrupted because of a mismatch in specified confidential
box No. Or, an interoffice F-code based bulletin board reception was interrupted because of a
mismatch in the specified F-code confidential box number.
U03700
Confidential polling reception failed because the destination unit had no confidential polling
transmission capability or data was not accumulated in any box in the destination unit. Or,
interoffice F-code based bulletin board reception failed because the destination unit had no F-
code based bulletin board transmission capability, or data was not stored in any F-code
confidential box in the destination unit.
U04000
The confidential box specified for confidential transmission was not registered in the destination
unit. Or, in interoffice F-code based transmission mode, the specified F-code box number was
not registered in the destination unit. Or, the destination was being accessed.
U04100
Confidential transmission failed because the destination unit had no confidential capability. Or,
F-code based transmission failed because the destination unit had no F-code based reception
capability.
U04200
In encrypted transmission, the specified encryption box was not registered in the destination unit.
U04300
Encrypted transmission failed because the destination unit had no encrypted communication
capability.
U044XX
Communication was interrupted because of an encryption key error during encrypted
transmission (refer to page 1-4-10 "U044XX error code table").
U04500
Encrypted reception was interrupted because of a mismatch in encryption keys.
U05000
In transmission with a specified number, the set number of originals was different from the
number of transmitted originals.
U05100
Password check transmission was interrupted because the permit ID did not agree.
U05200
Password check reception was interrupted because the permit ID did not agree.
U05300
Destination unit in password check reception mode did not receive data because the permit ID
did not agree.
U09000
G3 communication was attempted but failed because the destination unit was a G2 machine.
U12000
Relay broadcast was requested from a command station but memory overflowed during
reception. Or, in F-code based relay reception, memory overflowed.
U12100
Relay was commanded but memory overflowed in the destination unit (relay station).
U14000
Memory overflowed during confidential reception. Or, in F-code based confidential reception,
memory overflowed.
U14100
Memory overflowed in the destination unit during confidential transmission. Or, in interoffice F-
code based transmission, memory overflowed in the destination unit.
U19000
Memory overflowed during memory reception.
U19100
Memory overflowed in the destination unit during transmission.
U19200
Memory transmission failed because a decoding error occurred.
U19300
Transmission failed because an error occurred during JBIG encoding.
U19400
Reception failed because an error occurred during JBIG decoding.
Description
3DB
1-4-3

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Km-4030Km-3530

Table of Contents