Kyocera Mita KM-2530 Service Manual page 127

Hide thumbs Also See for KM-2530:
Table of Contents

Advertisement

Maintenance
item No.
U244
Method for the volume switch
1. Move the original insertion guides to check the detection status of the original size width switch.
The detected original width is displayed as a numerical value with the decimals omitted.
For example, if any value between 105 and 139 is displayed when the original insertion guides are adjusted
for A4R paper, it indicates that the original width is detected correctly.
2. To return to the screen for selecting an item, press the stop/clear key.
Completion
Press the stop/clear key at the screen for selecting an item. The screen for selecting a maintenance item No. is
displayed.
Description
Numerical
Original width to be detected
value
000
49.664
A5R
50.176
61.440
61.952
B5R
103.936
104.448
Folio/A4R
139.264
139.776
146.432
B4/B5
146.994
197.120
197.632
×
CF (11"
15")
197.720
223.232
A3/A4
256
×
1
1
5
/
"
8
/
"
2
2
×
1
8
/
"
14"/
2
×
1
8
/
"
11"
2
×
11"
17"/
×
11"
15"/
×
1
11"
8
/
"
2
2DF
1-4-37