8. Remove the film that fixes the three positive
connectors of the power source PCB from the
optional interface mounting plate.
Important: Dispose of the film that has been
removed.
9. Connect the FAX-PCB-Power cable to
connector CN1 on the auxiliary power source
PCB assembly.
10. Connect the three positive connectors on the
power board to the corresponding connectors
on the auxiliary power source PCB assembly,
as follows.
• White positive connector → TB1 (white)
• Green positive connector → TB2 (green)
• Small white positive connector → TB3
Optional interface
mounting plate
Figure 1-3-133
FAX-PCB-Power cable
Auxiliary power source
PCB assembly
Figure 1-3-134
Green positive
connector
Small white positive
connector
White positive
connector
Figure 1-3-135
2DF
Film
CN1
CN1
Auxiliary power source
PCB assembly
1-3-61