Kyocera Mita KM-2530 Service Manual page 628

Hide thumbs Also See for KM-2530:
Table of Contents

Advertisement

3DB
Maintenance
item No.
U611
G3 cable equalizer
Description
Sets the G3 cable equalizer.
Start
1. Press the start key. The screen for selecting an item is displayed.
2. Press the appropriate item.
The screen for the selected item appears.
Display
REG. G3 TX EQR
REG. G3 RX EQR
Setting the G3 transmission cable equalizer
Perform the following adjustment to make the equalizer compatible with the line characteristics.
1. Change the setting using the numeric keys.
Display
1: 0
2: 18
3: 36
4: 72
2. Press the start key. The value is set.
3. To return to the screen for selecting an item, press the stop/clear key.
Setting the G3 reception cable equalizer
Perform the following adjustment to make the equalizer compatible with the line characteristics.
1. Change the setting using the numeric keys.
Display
1: 0
2: 18
3: 36
4: 72
2. Press the start key. The value is set.
3. To return to the screen for selecting an item, press the stop/clear key.
Completion
Press the stop/clear key at the screen for selecting an item. The screen for selecting a maintenance item No. is
displayed.
1-3-20
Description
Description
Sets the G3 transmission cable equalizer.
Sets the G3 reception cable equalizer.
Description
0 km
1.8 km
3.6 km
7.2 km
Description
0 km
1.8 km
3.6 km
7.2 km