2DF
Code
Contents
C1010
Upper lift motor problem
• When the upper drawer is inserted,
the upper lift limit switch does not turn
on within 6 s of the upper lift motor
turning on and the upper lift limit
switch does not turn on by turning off
the upper lift motor for 200 ms and
retrying twice.
• During copying, the upper lift limit
switch does not turn on within 200 ms
of the upper lift motor turning on.
C1020
Lower lift motor problem
• When the lower drawer is inserted,
the lower lift limit switch does not turn
on within 6 s of the lower lift motor
turning on and the lower lift limit
switch does not turn on by turning off
the lower lift motor for 200 ms and
retrying twice.
• During copying, the lower lift limit
switch does not turn on within 200 ms
of the lower lift motor turning on.
C1030
Desk upper lift motor problem
• When the upper drawer of the paper
feed desk* is inserted, the desk upper
lift limit switch does not turn on within
6 s of the desk upper lift motor turning
on and the desk upper lift limit switch
does not turn on by turning off the
desk upper lift motor for 200 ms and
retrying twice.
• During copying, the desk upper lift
limit switch does not turn on within
200 ms of the desk upper lift motor
turning on.
1-5-30
Causes
Check procedures/corrective measures
Broken gears or
Replace the upper lift motor.
couplings of the
upper lift motor.
Defective upper
Check for continuity across the coil. If
lift motor.
none, replace the upper lift motor.
Poor contact of
Reinsert the connector. Also check for con-
the upper lift mo-
tinuity within the connector cable. If none,
tor connector ter-
repair or replace the cable.
minals.
Defective upper
Check if CN13-B9 on the main PCB goes
lift limit switch.
low when the upper lift limit switch is turned
off. If not, replace the upper lift limit switch.
Poor contact of
Reinsert the connector. Also check for con-
the upper lift limit
tinuity within the connector cable. If none,
switch connector
repair or replace the cable.
terminals.
Broken gears or
Replace the lower lift motor.
couplings of the
lower lift motor.
Defective lower lift
Check for continuity across the coil. If
motor.
none, replace the lower lift motor.
Poor contact of
Reinsert the connector. Also check for con-
the lower lift motor
tinuity within the connector cable. If none,
connector termi-
repair or replace the cable.
nals.
Defective lower lift
Check if CN13-B15 on the main PCB goes
limit switch.
low when the lower lift limit switch is turned
off. If not, replace the lower lift limit switch.
Poor contact of
Reinsert the connector. Also check for con-
the lower lift limit
tinuity within the connector cable. If none,
switch connector
repair or replace the cable.
terminals.
Broken gears or
Replace the desk upper lift motor.
couplings of the
desk upper lift
motor.
Defective desk
Check for continuity across the coil. If
upper lift motor.
none, replace the desk upper lift motor.
Poor contact of
Reinsert the connector. Also check for con-
the desk upper lift
tinuity within the connector cable. If none,
motor connector
repair or replace the cable.
terminals.
Defective desk
Check if CN1-5 on the desk main PCB
upper lift limit
goes low when the desk upper lift limit
switch.
switch is turned off. If not, replace the desk
upper lift limit switch.
Remarks