3CM
Maintenance
item No.
U608
Setting transmission
Description
Makes settings regarding fax transmission.
Start
1. Press the start key. The screen for selecting an item is displayed.
2. Press the appropriate item.
The screen for the selected item appears.
Display
ERROR
DIS-2 RES
RTN CHECK
TX ECHO
RX ECHO
ECM TX
ECM RX
TCF CHECK
CED FREQ.
Setting the method to process errors
Selects if transmission is to be treated as an error if an RTN or PIN signal is received. If it is treated as an error,
an alarm sounds and a transmission report is output.
1. Enter 1 or 2 using the numeric keys to change the setting.
Display
1: OK
2: ERROR
2. Press the start key. The value is set.
3. To return to the screen for selecting an item, press the stop/clear key.
Setting the number of times of DIS signal reception
Sets the number of times to receive the DIS signal to once or twice. Used as one of the correction measures for
transmission errors and other problems.
1. Enter 1 or 2 using the numeric keys to change the setting.
Display
1: ONCE
2: TWICE
2. Press the start key. The value is set.
3. To return to the screen for selecting an item, press the stop/clear key.
Setting the reference for RTN signal output
Sets the error line rate as the reference for RTN signal output. If transmission errors occur frequently due to the
quality of the line, they can be reduced by lowering this setting.
1. Change the setting using the numeric keys.
Display
1: 5
2: 10
3: 15
4: 20
2. Press the start key. The value is set.
3. To return to the screen for selecting an item, press the stop/clear key.
1-3-14
Description
Description
Sets the method to process errors.
Sets the number of times of DIS signal reception.
Sets the reference for RTN signal output.
Sets the waiting period to prevent echo problems at the sender.
Sets the waiting period to prevent echo problems at the receiver.
Sets ECM transmission.
Sets ECM reception.
Sets the criteria for receiving a TCF signal 1.
Sets the frequency of the CED signal.
Description
Transmission is not treated as an error.
Transmission is treated as an error.
Description
Responds to the first signal.
Responds to the second signal.
Description
Error line rate of 5%
Error line rate of 10%
Error line rate of 15%
Error line rate of 20%