15. Connect the three positive connectors on the
power board to the corresponding connectors
on the auxiliary power source PCB, as
follows.
• White positive connector → TB1 (white)
• Green positive connector → TB2 (green)
• White positive connector → TB3
16. Fit the catch on the auxiliary power unit into
the mount hole in the copier, and fasten the
auxiliary power unit into place with one M3 ×
06 chrome binding screw.
1-3-37-1
1-3-38
Green positive
Auxiliary power
connector
source PCB
White positive
White positive
connector
connector
Figure 1-3-71
Catch
Mount hole
Figure 1-3-72
M3 × 06 chrome
binding screw