4. Close the conveying cover and the front
cover.
5. Remove the two screws and then remove the
ejection cover with the mounting plate.
6. Remove the two screws and then remove the
inner ejection cover.
7. Remove the screw located at the front of the
static charge eliminator of the copier, fit the
flat spring ejection from the lower side, and
secure it with the removed screw.
Ejection cover
Figure 1-3-109
Screws
Figure 1-3-110
Flat spring ejection
Figure 1-3-110-1
2DF
Screws
Inner ejection
cover
Screw
1-3-51