Minimum startup configuration

Field Replaceable Units (FRU)
If the server does not start up or other problems occur, it may be necessary to
take the system down to its most basic configuration in order to isolate the
defective component.
The minimum startup configuration consists of the following components and
cables:
Component
System board
CPU0 with CPU heat sink
1 memory module
1 Power supply unit
Table 13: Minimum startup configuration - components
Cable
2 SATA cables
Table 14: Minimum startup configuration - cables
Ê Shut down the server as described in section
node" on page
Ê Take the system down to its minimum startup configuration.
Ê Connect a keyboard, mouse and display to the server.
Ê Switch on the server as described in section
on page
64.
V
CAUTION!
Since the fan module is not included in the minimum startup
configuration, the server must be shut down immediately after the
diagnostic process is complete (POST phase has been passed).
CX250 S2
Notes and reference
no TPM or expansion cards installed
installed in slot A1 or C1, see section
sequence" on page 172
Notes and reference
45.
Upgrade and Maintenance Manual
"Shutting down the server
"Switching on the server node"
Appendix
"Memory
263