Re-Installing The Ufm; Concluding Steps - Fujitsu PRIMERGY CX250 S2 Upgrade And Maintenance Manual

Server node
Hide thumbs Also See for PRIMERGY CX250 S2:
Table of Contents

Advertisement

System board and components
9.2.3.4

Re-installing the UFM

Ê Connect the UFM board to the system board and secure the UFM module
on the UFM spacer with the nylon screw as described in
board" on page
Destroying the defective UFM board
V
CAUTION!
The UFM board contains customer information (e.g. IP address, license
numbers). After replacing the UFM, hand the defective UFM board over
to the customer. If the customer requests disposal of the defective UFM
board, proceed as follows:
Figure 129: Destroying the defective UFM board
Ê Use a pair of combination pliers (1) and flat nose pliers (2) to break
the UFM board in half as shown.
9.2.3.5

Concluding steps

Perform the following procedures:
"Installing the server node in the server enclosure" on page 63
Ê
222
215.
Upgrade and Maintenance Manual
"Installing the UFM
CX250 S2