Figure 102: Removing the processor heat sink CPU1 (B)
Ê Carefully turn the heat sink back and forth to detach it from the processor (1).
I
This may be necessary due to the adhesive quality of the thermal
paste located between the heat sink and processor.
V
CAUTION!
Pay special attention not to damage any system board components
surrounding the processor socket.
Ê Lift the heat sink out of the chassis (2).
Ê Thoroughly clean residual thermal paste from the surface of the heat sink
and the processor using a lint-free cloth.
CX250 S2
Upgrade and Maintenance Manual
Processors