Installation

2.2
Installation
2.2.1

Installation Procedure

Install the SLM-7650 into the equipment rack as follows:
1. Carefully lift the modem into the selected position in the equipment rack. Refer
2. Connect the cables to the proper locations on the rear panel.
Notes:
1. To allow proper cooling of the unit, the modem shall be positioned in a manner
2. If there is any problem with the installation, contact Comtech EF Data's
2.2.2

External Modem Connections

2.2.2.1
Power Entry
Figure 1-2 for unit dimensional envelope.
to allow an uninterrupted airflow around the unit, including no blockages in front
of the fan assembly.
Customer Support Department.
Optional G.703 Card

Figure 2-1. Rear Panel

Table 2-1. Modem Rear Panel Connectors

Input Power
Input Voltage
Connector Type
Fuse Protection
AC Option
60W maximum, 50W typical
90 to 132, or 175 to 264 VAC
Unit switches range automatically
I.E.C.
2A slo-blo
Line and neutral fusing
5 mm type fuses
2–2
Rev. 3
MN/SLM7650.IOM