Comtech EF Data SLM-7650 Installation And Operation Manual page 157

Comtech ef data satellite modem installation and operation manual
Table of Contents

Advertisement

SLM-7650 Satellite Modem
Remote Control Specifications
Interface Loop
Command:
Timing
Response:
Status:
Response:
Interface
Buffer Size
Interface
Command:
Buffer Size
Response:
(Bit Format)
Status:
Response:
Interface
Command:
Buffer Size
Response:
(Milli-second
Format)
Status:
Response:
Interface
Command:
Buffer Center
Response:
Interface
Command:
Buffer
Response:
Programming
Status:
Response:
Interface
Command:
Receive
Response:
Framing
Structure
Status:
Response:
Interface
Command:
Substitute
Response:
Pattern
Status:
Response:
Interface
Command:
Read Error
Response:
Select
Status:
Response:
<add/ILT_xxx'cr'
>add/ILT_xxx'cr''lf']
<add/ILT_'cr'
>add/ILT_xxx'cr''lf']
<add/IBS_nnnnnnn'cr'
>add/IBS_nnnnnnn'cr''lf']
<add/IBS_'cr'
>add/IBS_nnnnnnn'cr''lf']
<add/IBS_nn'cr'
>add/IBS_nn'cr''lf']
<add/IBS_'cr'
>add/IBS_nn'cr''lf']
<add/IBC_'cr'
>add/IBC_'cr''lf']
<add/IBP_xxxx'cr'
>add/IBP_xxxx'cr''lf']
<add/IBP_'cr'
>add/IBP_xxxx'cr''lf']
<add/IRFS_ff_ssss'cr'
>add/IRFS_ff_ssss'cr''lf']
<add/IRFS_ff'cr'
>add/IRFS_ff_ssss'cr''lf']
<add/ISP_xxxxxx'cr'
>add/ISP_xxxxxx'cr''lf']
<add/ISP_'cr'
>add/ISP_xxxxxx'cr''lf']
<add/IRE_xxxxxx'cr'
>add/IRE_xxxxxx'cr''lf']
<add/IRE_'cr'
>add/IRE_xxxxxx'cr''lf']
Where: xxx = ON or OFF.
Buffer size programming is supported in two formats; bits, or
milli-seconds. The selected format must be chosen using
the buffer programming command (IBP_). If the buffer is to
be programmed in milli-seconds and plesiochronous slips
are required use the receive framing structure command
(IRFS_) to define the proper framing format.
Where: nnnnnnn = 32 to 1048576, in 16 bit increments.
Where: nn = 0 to 48 milli-seconds in 1 milli-second
increments (buffer size in milli-seconds).
The maximum buffer size, in milli-seconds, is data rate
dependant. Maximum buffer size cannot exceed 48 milli-
seconds or 1048576/(Data Rate) seconds, whichever is
lower.
Centers the buffer.
Where: xxxx = BITS or MS (milli-seconds).
Where:
ff = T1, T2, E1, or E2 (frame type).
ssss = NONE, G704, G742, G743, G745, or G747
(framing structure).
Notes:1. Valid T1 frame structures are NONE, and G704.
2. Valid T2 frame structures are NONE, G704, G743,
and G747.
3. Valid E1 frame structures are NONE, and G704
4. Valid E2 frame structures are NONE, G704, G742,
and G745.
Where: xxxxxx = 2047, MIL188 or OFF.
Note: Transmit 2047 or MIL188 Pattern.
Where: xxxxxx = 2047, MIL188 or OFF.
Note: Receive 2047 or MIL188 Pattern.
A–15
Revision 4
MN/SLM7650.IOM

Advertisement