P-Series Xq Emulation - Printronix P8000 Series Administrator's Manual

Cartridge ribbon printer
Hide thumbs Also See for P8000 Series:
Table of Contents

Advertisement

P-Series XQ Emulation

Printer
Protocol
(from page 125)
P-Series
XQ
Control Code
Define CR
06
Code
8.0 LPI*
CR = CR*
10.3 LPI
CR = CR + LF
6.0 LPI
HS Print
VFU Select
char 02 STX*
EVFU*
char 03 ETX
DVFU
char 09 HT
CVFU
Disable
Control Code 06
Control Code 06 defines the function of ASCII code hex 06 (ACK). You can
select an alternate line spacing of 6, 8, or 10.3 LPI.
Define CR Code
This option controls the action of the printer when it receives a Carriage
Return code (hex 0D) from the host computer. If this feature is enabled, each
time the printer receives a Carriage Return, it inserts an additional Line Feed
code (hex 0A) into the data stream. Do not use this feature if the host
computer sends line feeds to the printer.
CR = CR (factory default). Does not insert an extra line feed after each
carriage return.
CR = CR + LF. Inserts an extra line feed after each carriage return. The
next print position will be print position 1 of the next line.
Autowrap
This option defines the printer action when print data is received past the
forms width setting.
With LF+CR (factory default). Performs an automatic carriage return and
line feed when data is received past the forms width.
With CR. Performs an automatic carriage return (without line feed) when
data is received past the forms width.
Disable. Discards any data past the forms width.
Autowrap
Define LF
Code
With LF+CR*
LF = CR + LF*
With CR
LF = LF
Disable
Slew
Upr. Case
Select
Relative
Disable*
1 to 15 lines*
Enable
1 to 16 lines
P-Series XQ Emulation
* = Factory Default
Compressed
Elong/Alt.
Print
Font
char 01 SOH*
Elng=BS Font=SO*
char 03 ETX
Elng=SO Font=BS
char 09 HT
153