Trunc Dyn Data

This submenu allows the user to truncate the dynamic data up to the
maximum data length specified in Create Mode.
Disable (factory default). If the dynamic data exceeds the maximum data
length, an error will report.
Enable. If the dynamic data exceeds the maximum data length, the data
truncates.

Error Report

Sets the error reporting capability for IGP/PGL forms.
On (factory default). Form boundary error checking reported. Any
element which falls off the current page is reported as an error.
Debug Mode. The printer is put in debug mode whenever a form is
defined in Create Form mode. Each line of the Create Form is printed
along with an error if one occurred. This is the same functionality as if
there were a slash (/) entered before the Create Form Name.
Fault. When an error occurs, the error is printed and the message "IGP/
PGL ERROR" appears on the printer front panel. The printer then stops
printing and goes offline. The error must be cleared before the printer can
resume normal operation.
Host. When an error occurs, the error message is sent back to the host.
Off. No form boundary checking. Graphic elements appear clipped if they
are beyond the page boundaries.
Select Font
Allows you to choose from various character sets, including IGP/PGL
Standard sets, 256 character multinational sets, and UTF-8 encoded
Unicode™.