- Adding New Devices
[1]
Enter the Installer Menu, select the "02.ZONES/DEVICES" option (see section 3.2) and then select the
"ADD NEW DEVICE" option.
Device Enrollment
[2]
If enrollment is successful the display reads "DEVICE ENROLLED" (or "ID accepted") and then shows
the device details - see [3]. However, if the enrollment fails, the display will advise you the reason for
failure for example: "ALREADY ENROLLED", "UNKNOWN DEVICE", "WRONG ID No." or "NO FREE
LOCATION".
[3]
The display shows the device details and the first available free Zone number for example: "Z01:Motion
Sensor > ID No. 120-1254" (or "K01:Keyfob / S01:Siren etc. depending on the type of the enrolled device).
If you wish to assign the device to another zone number, for example, "Zone 05", click the
until the display reads "Z05:Motion Sens", or type in the zone number using the control panel keypad,
and then press
[4]
Select the configuration option you wish i.e. Location, Zone Type, Set Chime and Device Parameters
(Settings) and continue to part B to configure the device. At the end of each of the 4 configuration options,
the wizard will bring you automatically to the next configuration option.
You can also review the configuration of all parameters one by one by pressing repeatedly the
button.
[5]
After completing the configuration of the device the wizard brings you to the "Next Step" menu with the
following 3 options:
NEXT Device
MODIFY Same Dev.
changes in the device, if needed.
EXIT Enrollment
"Zones / Devices" menu.
Location (name) setting:
[6]
If you wish to review or change the Location (name) setting, press the
the next option.
[7]
When entering the Location menu, the display shows the default Location (
selected Location (marked with ). If you wish to change the Location name, scroll in the location menu
and select the name you wish (for example, Living room, Kitchen etc.). – see "Location List" above. The
list contains 26 fixed location names plus 5 custom names that can be defined using the
06.CUSTOM NAMES
Note: A quick shortcut procedure may be used by keying the 2 digit serial No. of the Location shown in
the Location List above, which takes you directly to the corresponding location name.
(
) A list of factory default locations per each zone is provided in APPENDIX E. Event Codes.
Zone Type setting:
[8]
If you wish to review or change the Zone Type setting, press the
next option.
The zone type determines how the system handles alarms and other signals sent from the device. Upon
[9]
enrollment of a new sensor you must select a suitable zone type. The list of available Zone Types and the
explanation for each zone type is provided above.
D-303222 PowerMaster-10 / PowerMaster-30 Installer's Guide
to confirm.
Brings you back to Step 2 to enroll the next device.
Returns you back to the beginning of Step 4 (i.e. "Location") to make further
Exits the enrollment procedure and returning to Step 1 bringing you back to the
option in the Installer menu. See section 3.8.
button, otherwise scroll to
) or if changed, the presently
button, otherwise scroll to the
button
39