2.3.10 Connecting AC Power to the Control Panel

WARNING!
DO NOT USE AN OUTLET CONTROLLED BY A WALL SWITCH.
Note: This equipment should be installed in accordance with Chapter 2 of the National Fire Alarm Code, ANSI/NFPA
72, (National Fire Protection Association).
Connect the power cable and close the control panel as shown in Figure 3.23. The socket outlet shall be
installed near the equipment and shall be easily accessible.
PERFORM STEPS 1 & 2 ON A WORKBENCH BEFORE THE MOUNTING
1
1. Thick cable entry: Pull out a desired wiring
plastic cap (1 of 4).
1. Insert the power cable through the desired wiring
channel (A). Route it to the power supply unit (E)
and connect its 2 wires to the power supply
terminal block (F) with a screwdriver. Fasten the
screws tightly. Verify that the wires are properly
fastened! Fasten the power cable by its clamp
(B or C) and close the safety cover (D).
2. Connect the power supply output cable (G) to the
power connector (H) in the front panel.
D-303222 PowerMaster-10 / PowerMaster-30 Installer's Guide
POWER CABLE CLAMP EXTRACTION
POWER CONNECTION FOR ALL COUNTRIES EXCEPT USA
2
2. Extract cable clamp for use in the next step.
A. Wiring channels
B. For thin cable
C. For thick cable (reversed clamp)
D. Safety cover
E. Power supply unit
F. Power supply terminal block
G. Power supply output cable
H. Power connector
(*) Do not route wiring in this area, to enable proper
closure of the control panel.
29