Advertisement

05:QUICK ARM
06:BYPASS ARM
Notes: To comply with EN requirements, "manual bypass" or "force arm" must be
07:LATCHKEY ARM
08:DISARM
OPTION
46
A: "normal" - The exit delay is exactly as defined.
B: "restart>reentry" - The exit delay restarts when the door is reopened during exit
delay. The restart occurs once only. Restarting the exit delay is helpful if the user
re-enters immediately after going out to retrieve an item that he left behind.
C: "end by exit" - The exit delay expires (ends) automatically when the exit door is
closed even if the defined exit delay time was not completed.
Option settings: normal (default); restart>reentry and end by exit.
Define whether or not the user will be allowed to perform quick arming or not. Once
quick arming is permitted, the control panel does not request a user code before it arms
the system.
Option settings: OFF (default) and ON (default in USA).
Define whether or not the user will be allowed to manually Bypass individual zones, or
allow the system to perform automatic bypassing of open zones during the exit delay
(i.e. "force arm"). If a zone is open and "forced arming" is not permitted, the system
can not be armed and "NOT READY" is displayed. If "no bypass" is selected, neither
manual bypassing nor force arming is allowed which means that all zones must be
secured before arming.
Option settings: no bypass (default); force arm and manual bypass (default in USA).
selected.
The option "force arm" is not applicable in the UK.
Here you determine whether the system can be armed in the "Latchkey" mode. If the
system is armed this way, a "latchkey" message will be reported by voice (PowerMaster-
30) or SMS message to users (see note) upon disarming by a "latchkey user" (users 5-8
or keyfob transmitters 5-8 in PowerMaster-10 system / users 23-32 or keyfob
transmitters 23-32 in PowerMaster-30 system). This mode is useful when parents at
work want to be informed of a child's return from school.
Note: To enable the reporting, you must configure the system to report "
Private users (Latchkey belongs to the "alerts" group of events). Refer to section 3.6.4
REPORTED EVENTS
option in both "VOICE REPORT" & SMS REPORT" menus.
Option settings: OFF (default) and ON.
Certain regulations require that the when the system is armed in AWAY mode, it may not
be disarmed from the outside of the house (such as by keyfobs) before entering the
protected premises and activating an "Entry Delay" zone. To answer this requirement,
the PowerMaster-10 / PowerMaster-30 provides you with the following configurable
options to disarm the system:
A: At "any time".
B: During entry delay using keyfob devices only ("on entry keyfob").
C: During entry delay by code only using PowerMaster-10 / PowerMaster-30 panel
keypad ("on entry keypad").
D: During entry delay using keyfobs or by code using PowerMaster-10 / PowerMaster-30
panel keypad ("on entry all").
D-303222 PowerMaster-10 / PowerMaster-30 Installer's Guide