05:DUAL REPORT
11:RCVR1 ACCOUNT
12:RCVR2 ACCOUNT
Master Installer only
16:PSTN/GSM RCV1
17:PSTN/GSM RCV2
Master Installer only
D-303222 PowerMaster-10 / PowerMaster-30 Installer's Guide
Option settings: disabled (default); cellular and PSTN.
Important:
Only selected communication channels will be used by the system to
report event messages to Monitoring Stations. If none is selected, the
reporting to monitoring stations will be disabled.
Note:
When Cellular channel is selected then the priorities within he cellular will
be GPRS (IP) channel first, then GSM voice channel and last SMS
channel provided these channels have been enabled in section 3.6.3.
Here you determine whether or not to report events using PSTN and Cellular.
Option settings: disable (default) and PSTN & cellular.
Here you enter the respective 1
that will identify your specific alarm system to the 1
RCVR1 or RCV1) and a 2
will identify the system to the 2
Each of the Account numbers consists of 6 hexadecimal digits.
st
nd
Enter the 1
and 2
Account numbers in their corresponding locations. To enter
Hexadecimal digits, use the following table:
Entering Hexadecimal Digits
Digit
0.....9
0.....9
Keying
The PowerMaster-10 / PowerMaster-30 can be programmed to report the event
messages defined in the Report Events option (option 01) to two Alarm Format
Receivers via PSTN telephone line and/or GSM analog voice channel (if equipped with
GSM module), using standard PSTN alarm formats (i.e. SIA, Contact-ID and Scancom).
The reporting format is defined in the "PSTN Report Format" option (option 41).
Here you enter the two respective telephone numbers of the Alarm Format Receiver 1
st
located at the 1
Monitoring Station (16: PSTN/GSM RCV1) and alarm format Receiver
nd
2 located at the 2
Monitoring Station (17: PSTN/GSM RCV2).
Enter the telephone numbers of alarm format Receiver 1 and Receiver 2 in their
corresponding locations (including area code – maximum 16 digits). For further
programming information see the table below.
Note: If any of the phone numbers programmed herein contain an area code identical
to the area code of the PSTN telephone line to which the system is connected, you
AREA CODE
should refer to the
Digit
Keying Digit Significance
[#] [0]
The dialer waits 10 seconds or waits for dial tone, whichever comes
A
first and then dials. Applicable only at the 1
[#] [3]
The dialer waits 5 seconds for dial tone and goes on hook if none is
D
received. Applicable only at the 1
The dialer waits 5 seconds. Applicable only in the middle of the
[#] [4]
E
number.
To move the cursor and clear digits, use the "String Editor's" keys as described in
the table at the end of section 3.6.3.
st
Account (subscriber) number (11:RCVR 1 ACCOUNT)
nd
Account (subscriber) number (12:RCVR 2 ACCOUNT) that
nd
Monitoring Station (designated as RCVR2 or RCV2).
A
B
C
[#] [0]
[#] [1]
[#] [2]
option in section 3.6.2.and act as instructed there.
st
Monitoring Station (designated as
D
E
[#] [3]
[#] [4]
st
digit.
st
digit.
F
[#] [5]