Visonic PowerMaster-10 Installer's Manual page 37

Fully supervised wireless alarm control system
Hide thumbs Also See for PowerMaster-10:
Table of Contents

Advertisement

Enrollment Procedure
Refer to the device information in the device Installation Instructions, open the device and identify the Enroll
Button. For keyfobs and keypads use the AUX ' ' button. For gas detectors insert the battery.
Full-Enrollment Procedure (Enroll Now)
Press the Enroll button for 2-5 seconds until the LED turns ON and then release the button. The LED will extinguish or
may blink for few more seconds until the enrollment is completed. If enrollment is successfully completed, the
PowerMaster-10 / PowerMaster-30 sounds the "Happy Tune" and the LCD momentarily shows
and then reads the device details – see Step 3 in the chart below.
DEVICE ENROLLED
Pre-Enrollment Procedure (Enter ID.)
Enter the 7-digit ID number printed on the sticker attached to the device and press
a wired sensor into the wired zone use ID: 050-0001 or 050-0002.
1. A Wired sensor is enrolled to the wired zone input using the Pre-Enrollment procedure and ID number
050-0001/050-0002.
2. Keyfob enrolling can be performed also by the user (via USER SETTINGS menu).
3. Wireless detectors can be enrolled in zones 01-30 (PowerMaster-10) / 01-64 (PowerMaster-30).
4. Because of the high security encryption used, PowerG devices (including Keyfobs) cannot be used on
more than one system.
5. Wired magnetic contact or any other contact can be enrolled in any one zone in PowerMaster-10 and
any two zones in PowerMaster-30.
6. Carefully read the "Additional Information"
[1] etc. – see table at end of this section.
To enroll and configure a device, follow the instructions in the following chart (carefully read the "Additional
Information"
for each step according to the indicated step references
section):
Step 1
Select "ADD NEW
[1]
DEVICE" Option
02:ZONES/DEVICES
ADD NEW DEVICE
C. Configuring the Zone Location, Zone Type, Chime option and Device Parameters
1. A list of factory defaults is printed in APPENDIX G. Default and Programmed Zone Definitions. You may
fill out the blank columns even before you start and proceed to program according to your own list.
2. Steps 6 to 12 are applicable to sensors only.
36
Step 2
Enroll the device or
[2]
Enter the device ID
ENROLL NOW or
ENTR ID:XXX-XXXX
See Enrollment
& Pre-Enrolment
Procedures above
for each step according to the indicated step references
Step 3
[3]
Select a Zone number
Z01:Motion Sens
ID No. 120-1254
Z05:Motion Sens
ID No. 120-1254
D-303222 PowerMaster-10 / PowerMaster-30 Installer's Guide
to confirm. To enroll
[1] etc. – see table at end of this
Step 4
Configure zone &
device Parameters
Z10:LOCATION
Z10:ZONE TYPE
Z10:SET CHIME
Z10:DEV SETTINGS
NEXT Device
MODIFY Same Dev.
EXIT Enrollment
Step 5
[4]
[5]
Continue
to Part
B.
See
[4]
See
[5]

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Powermaster-30

Table of Contents