63:ZONE RESTORE
64:SYST.INACTIVE
65:TWO WAY VOICE
Send 2wv code
Voice <--> C.S.
Ringback time
Ambient level
(Return)
Master Installer only
for Send 2wv code /
Voice <--> C.S. /
Ringback time
Send 2wv code
Voice <--> C.S.
Ringback time
Ambient level
Refers to PowerMaster-30 with voice option only
62
Some Monitoring Stations require that following an alarm event from a specific zone,
the system will also report when the alarming zone has restored to normal.
Here you determine whether a zone restore will be reported or not.
Option settings: report enabled (default) and report disabled
The PowerMaster-10 / PowerMaster-30 can be programmed to report a "System
Inactive" event message (CID event 654) to the Monitoring Station if the system is not
used (i.e. armed) during a predefined time period.
Here you can enable the feature and determine the time period.
Option settings: report disabled (default); after 7 days; after 14 days; after 30 days;
and after 90 days.
Here you can configure the two way voice channel settings of the PowerMaster-30, as
follows:
Send 2 WV Code: Here you determine whether the system will send two-way voice
code to the Monitoring Station (to turn the Monitoring Station from data communication
to voice communication state) by using pre-selected SIA or Contact-ID communication
format only.
Voice <--> C.S.: Here you select the timeout for 2-way voice communication with
Monitoring Stations, or enable the Monitoring Station to ring back for 2-way voice function.
This option is applicable only after reporting an event to the Monitoring Station for listening
and speaking).
Ringback Time: Here you determine the period during which the Monitoring Station
can establish 2-way voice communication with the PowerMaster-30 (after 1 ring), if:
A. Alarm type message was received by Monitoring Station.
B. Ring Back function was selected [see "Voice <--> C.S." sub menu above].
Ambient Level: Here you select the ambient noise level of the installation. If it is a
relatively noisy environment, set it to High (default setting). If it is a very quiet
environment, set to Low.
To configure:
Press
to enter the
configure the communication channel you wish i.e.
Ringback time
Ambient level
Option settings: don't send (default); and send.
Option settings: disable (default); timeout 10 s; timeout 45 s; timeout 60 s; time out
90 s; timeout 2 m; and ringback.
Note: If "ring back" is selected, you should select "disable report" for private telephone
(see Option 01:REPORT EVENTS), otherwise the Monitoring Station will establish
communication with the PowerMaster-30 (after an event occurrence) in the normal
manner (and not after one ring).
Option settings: 1 minute (default); 3 minutes; 5 minutes; and 10 minutes.
Option settings: low (default); and high.
sub menu and then scroll, select and
65:TWO WAY VOICE
. When done, press
D-303222 PowerMaster-10 / PowerMaster-30 Installer's Guide
Send 2wv code
Voice <--> C.S.
to return.