Visonic PowerMaster-10 Installer's Manual page 20

Fully supervised wireless alarm control system
Hide thumbs Also See for PowerMaster-10:
Table of Contents

Advertisement

CONNECTING AC POWER USING INTERNAL AC/DC POWER SUPPLY UNIT
PERFORM STEPS 1, 2 & 3 ON A WORKBENCH BEFORE THE MOUNTING
1
4
7
1. Extract either plastic segment (will be used later)
2. Extract plastic segment (will be used later)
3. Knock out the plastic segment (left or right,
according to the power wiring direction)
4. Remove power supply terminals cover (E)
5. Insert the power cable through the desired wiring
channel, route it to the power supply unit and
connect its 2 wires to the power supply terminal
block with a screwdriver. Fasten the screws tightly.
Verify that the wires are properly fastened!
6. Insert plastic cap to the power cable entry
(extracted in step 1)
D-303222 PowerMaster-10 / PowerMaster-30 Installer's Guide
2
5
B
C
7. Fasten power cable by clamp (extracted in step 2)
8. Close power supply terminals cover
A. Internal AC/DC power supply unit
B. Power cable clamp options
C. For thin cable
D. For thick cable (reversed clamp)
E. Terminals cover
Figure 3.11 – Power Cable Wiring
6
A
8
D
3
E
19

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Powermaster-30

Table of Contents