Option
51:
PIEZO BEEPS
With Partition
disabled
51:
PIEZO BEEPS
With Partition enabled
52:
TROUBLE BEEPS
53:
MEMORY PROMPT
54:LOW-BAT ACK
55:BACK LIGHT
56:SCREEN SAVER
With Partition
disabled
Refers to PowerMaster-30 only
50
Configuration Instructions
Here you determine whether the panel will sound the exit/entry warning beeps during
exit and entry delays or not. An additional option is to mute the warning beeps only when
the system is armed "HOME".
Option settings: ON (default), OFF when home (default in USA) and OFF.
Note: When exit beeps are OFF, the happy (success) melody will still to sound toward
the end of an exit delay.
The volume level of the exit / entry beeps can be modified by pressing the
on the keypad to increase the volume, or by pressing the
volume.
Here you determine whether the panel will sound the exit/entry warning beeps during
exit and entry delays or not. An additional option is to mute the warning beeps only when
the system is armed "HOME".
The control panel's display is: Def:P1
The pushbuttons
partitions. Pressing each button repeatedly will toggle between each option.
Option settings:
(enable beeps), H (OFF when home) and
Notes:
When exit beeps are OFF, the happy (success) melody will still to sound toward the end
of an exit delay.
The volume level of the exit / entry beeps can be modified by pressing the
on the keypad to increase the volume, or by pressing the
volume.
Under trouble conditions, the panel sounder emits a series of 3 short reminder beeps
once per minute. Here you determine whether to enable or disable this reminder beeping
or just disable it at night. The "night" hours are defined in the factory but are usually from
8 PM (20:00) until 7:00 AM.
Option settings: ON (default in USA); OFF at night (default) and OFF.
Define whether or not the user will receive "Memory" indication that an alarm has been
activated.
Option settings: ON (default) and OFF.
Here you can activate or deactivate the "Low Battery Acknowledge" requirement from the
user whose keyfob's battery is low. For further information see User's Guide Chapter 6.
Option settings: OFF (default) – acknowledge not needed; ON – acknowledge required.
Here you determine whether the panel's back lighting will remain on at all times or will
turn on only when a key is pressed and turn off within 10 seconds if no further
keystrokes are sensed.
Option settings: always ON and OFF after 10 sec (default).
Certain regulations require that the system status display will not be exposed to
unauthorized persons. The Screen Saver option (when activated) replaces the status
display with "PowerMaster-10" / "PowerMaster-30" display if no key is pressed during
more than 30 seconds.
P2
,
, and
provide selection of the corresponding
D-303222 PowerMaster-10 / PowerMaster-30 Installer's Guide
button to decrease the
P3
(disable beeps).
button to decrease the
button
button

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Powermaster-30

Table of Contents

Save PDF