Visonic PowerMaster-10 Installer's Manual page 39

Fully supervised wireless alarm control system
Hide thumbs Also See for PowerMaster-10:
Table of Contents

Advertisement

02
Exit / Entry 2
03
Home Delay
04
Interior-Follower
05
Interior
06
Perimeter
07
Perimeter -
Follower
08
24hr Silent
09
24hr Audible
10
Emergency
11
Arming Key
12
Non-Alarm
17
Guard Key box
(
)
These Zone Types are useful mainly when you arm and disarm the system from inside the protected
premises. If you arm and disarm the system from outside (without tripping any sensor), such as using a
keyfob, it is preferred to use the other Zone Types.
38
Same as Exit / Entry 1 but allows to define a different entry delay. Used sometimes
for entrances closer to the panel. For configuring the Exit and Entry 2 delays, see
sections 3.5.1 & 3.5.2 - Installer menu
Used for Door/Window Contacts and Motion sensors protecting entrance doors to
interior living areas where you wish to move feely when the system is armed HOME.
Functions as a "Delayed" zone when the system is armed HOME and as a
"Perimeter Follower" zone when the system is armed AWAY.
Used for Door/Window Contacts and Motion sensors protecting the route between
the entrance door and the control panel. This zone is temporarily ignored by the
alarm system during entry/exit delay periods, otherwise provides instant alarm. (∗)
Used for Door/Window Contacts, Motion and glass-break sensors installed in interior
areas that need to be protected only when the system is armed AWAY but not
protected when the system is armed HOME. When tripped provides instant alarm.
Used for all type of sensors protecting the perimeter of the premises when the
system is armed both AWAY and HOME. When tripped provides instant alarm.
Used for all type of sensors protecting the perimeter of the premises but temporarily
ignored by the alarm system during entry/exit delay periods, otherwise provides
(
)
instant alarm.
Used to report alarm events from sensors (or manually activated buttons) to the
monitoring station or private telephones (as programmed) without activating the
sirens. Active 24 hours.
Used to report alarm events from sensors (or manually activated button) to the
monitoring stations or private telephones (as programmed) and also providing an
audible siren alarm. Active 24 hours.
Used for pendants and other emergency sensors and activators to initiate an
Emergency call to the monitoring stations or private telephones (as programmed).
An Arming key is a zone that can be used for arming and disarming the system by a
wired PowerG detector or by a magnetic contact PowerG device that is enrolled to a
zone. In addition, the alarm system may be armed / disarmed by a keyswitch when
connected to wired zones.
Used for non-alarm applications. For instance sensors or activators used for Chime
only, remote control, home automation etc. Not valid for PIR cameras.
A Guard Key zone is a 24H Zone. Since the Guard Key box is a hardwired unit, the
installation is done with a wired PowerG detector that is located inside the wall,
where the Guard Key box is installed.
03.CONTROL PANEL
D-303222 PowerMaster-10 / PowerMaster-30 Installer's Guide
(
)
options 02 and 03.