8.02.3 FLOPPY HOOK-UP

Mechanical Floppy Disk Installation:
The installation of the Floppy drives is done via a standard IBM 34-pin flat ribbon cable
that connects to J4.
DIAGRAM 8-3: Floppy Disk Cable
The following list includes approved vendors for the J4 connector's mating parts:
Amp 746285-8 [optional strain relief: 499252-6],
Robinson Nugent IDS-C34PK-TG,
Thomas & Betts 622-3430 [optional strain relief: 622-3441].
(34-pin flat cable connector).
Enhanced Floppy Mode:
In order to connect your 2.88MB Floppy drive, simply indicate the proper Floppy disk
drive in the AWARD Setup program. It is not necessary to set the HDOUT and EDOUT
media detection signal jumpers, explained in the following pages.
Installing IDE, Floppy & SCSI Devices
8-11