7-4
Programming with Scrollers
Programming with Scrollers
The example below uses the numeric keypad to assign the frame number. You can,
however, address the scroller using the the Frame wheel (wheel 2). Using the wheel
obviates pressing [FRAME].
Example: select scroller channel 10, set the dimmer level to 100%, set the scroller frame
at 2, and record as memory 2.
Keypresses
1. Select channel 10
2. Press [FULL]
3. Press [FRAME]
4. Enter 02 on the numeric
keypad.
Press [=]
5.
6. Enter 2 on the numeric keypad
7. Press [STORE]
Spark
Results/Comments
Channel 10's dimmer is at 100%.
If you elect to assign the frame value using
the wheel, skip steps 3 and 4.
Enter the frame number as 2 digits.
Memory appears in the command line. If the
system configuration is for USA you can
press [MEMORY] instead of [=].
The message Memory 2 Stored! is
displayed. The editor is not cleared.
Need help?
Do you have a question about the Spark and is the answer not in the manual?
Questions and answers