Patching dimmers to channels

1. Go to the Channel Patch menu – [MENU] [1] [ENTER].
2. Press F1 Assign Dimmers.
3. Enter a dimmer number in answer to the prompt.
4. Press F3 To Channel.
5. Enter a channel number in answer to the prompt.
6. Press F1 Store.
See Chapter 20 - Channel and Scroller Patching, for further information.

Patching scrollers to channels

1. Go to the Scroller Patch menu - – [MENU] [20] [ENTER].
2. Select a scroller by entering the scroller number on the numeric keypad or by [+]
and [-] to move the cursor (the colored bar) to the scroller you want.
3. Press F1 Assign To Channel.
4. Enter the channel number in answer to the prompt.
5. Press F1 Store.
See Chapter 20 - Channel and Scroller Patching, for further information.

Patching and addressing moving lights

1. Go the Mix Output menu– [MENU] [19] [ENTER].
2. Select the type of moving light you are using from the Device List. If the moving
light you are using does not appear in the Device List you can define it yourself.
When you define a device yourself, consult the manufacturer's specifications.
Device definitions can be stored to disk. See Mix Output menu.
3. Assign spot numbers to the selected device.
4. Assign Output Addresses to the spot numbers.
5. Exit the Mix Output menu.
See Chapter 21 - Spot Management, for further information.