Configuring Link Traffic Test Parameters - Brocade Communications Systems WFT-2D User Manual

San user manual
Table of Contents

Advertisement

7.

Configuring link traffic test parameters

You can conifigure these parameters to improve accuracy and to measure link performance on
stress conditions with more traffic.
1. Enter the number of frames to use in the traffic test in the Number of Frames field.
2. Enter the duration you want the test to run in the Duration Hours and Minutes fields.
3. Enter the frame size you want for the traffic test in the Frame Size field.
Brocade Network Advisor SAN User Manual
53-1003154-01
TABLE 80
Status Detail messages
Operation/Test
Distance between ports
Reverse Optical Loopback Test
Roundtrip link latency
Buffers required
Link Traffic Test Configuration
used
If any test fails, that test displays
as failed and a Failure report
displays.
HBA Electrical test successful
HBA Electrical test failed
Click Close on the Diagnostic Port Test dialog box.
Minimum is 1 million (default). Maximum is 2,147,483,647 million.
This option is mutually exclusive of frames option.
Minimum is 0 hours and 1 minute (default). Maximum is 99 hours and 59 minutes.
Minimum is 36 bytes. Maximum is 2236 bytes. Default is 1024 bytes.
Possible message
Approximate distance between the ports is numerical_value meters.
Successfully completed Reverse Optical Loopback Test.
Reverse Optical Loopback Test failed.
Roundtrip link latency: numerical_value nano-seconds.
Buffers required: numerical_value
No. of test frames: numerical_value Million
Duration of test (HH:MM): hours:minutes
Test frame size: numerical_value Bytes
Payload Pattern: pattern_name or frame_data
FEC (enabled/active): Yes/No
CR (enabled/active): Yes/No
Start time: day month date hour:minute:seconds year
End time: day month date hour:minute:seconds year
NOTE: If you do not set a payload pattern, results do not show payload
pattern.
Sample failure report :
Errors detected (local): CRC, Bad_EOF, Enc_out
Errors detected (remote): CRC, Bad_EO
Run portstatsshow and porterrshow for more detail on the errors.
Successfully completed Electrical Loopback Test on port
HBA_port_number of the HBA HBA_node
Electrical Loopback Test failed on port HBA_port_number of the HBA
HBA_node
27
FC troubleshooting
1061

Advertisement