5 June 1992
[D]
[C]
4. Remove the copier right cover [A] (2 screws) and plastic cap [B]. Pass the
4P connector [C], fiber cable [D], and ground wire [E] of the interface
harness through the lower hole [F] of the right cover. Then, reinstall the
right cover.
NOTE: Since the 2P connector is not used for this finisher installation,
keep it in the copier.
5. Install the relay guide [G] (2 screws).
6. Bring the finisher near the main copier and confirm that the height of the
relay guide exit plates [H] are aligned between the finisher entrance
plates [I].
NOTE: If not, adjust the height of the relay guide exit plates (loosen the 2
screws [J]).
[E]
[F]
[J]
[A]
[B]
[H]
19
INSTALLATION
[I]
[G]